Home | Contact Us
Building Application | Marine Application

Building Applications :
 
Resonac M
The Finishing Touch in the Suppression of Vibration Generated Noise



Steel body shells and floors of carriages protected with Resonax M
Vibration Damping between 70 & 80 Hz
Description of Damping Coating
Vibration Decay Rate (dB/sec)
Description of Plate    
Steel (1mm)

Uncoated plate
1.5mm (dry) Resonac M
3mm (dry) Resonac M

3
115
224
Aluminium (3mm) Uncoated plate
1.5mm (dry) Resonac M
3mm (dry) Resonac M
11
104
555



Resonac M anti drumming compound for cladding panels and between studio walls

Toxicity

NES 713, Issue 3 Toxicity Test. Toxicity Index 0.34. The Results of the quantitative analysis for toxicity show the following results :
N < 0.15%       C14.94%       S<0.15%
The results of the qualitative analysis show the pressence of: C, O, AI, Si, K, Ca, Fe
.

Smoke Emission
When tested to BS 6853: 1999
Annex D8. 4 "Panel Test"
Specimen 1 Specimen 2 Specimen 3
Ao(on max)
3.38
3.64
3.51
Ao(on end)
3.26
3.57
3.41
Ao(off)
3.79
4.04
3.91
Spread of Flame
Class 1 to BS 476: Part 7: 1997 on non combustible surfaces
Fire Propagation
An Index performance 1 of 1.2 and a sub-index i 1 of 0 to BS 476: Part 6: 1989 on aluminium sheet. The combination of the fire propagation test and the spread of flame test gives Class 'O' to the 1991 Building Regulations.
M1 Classification
Fire Tests according to French regulation 'Arrete' 28.09.1991
Fire Number 9004722 CEMATE/1

Resonac M coated vitreous enamel panels